Product Description

1. Maximum voltage between any terminal and earth ground: 1000 V
2. Fuse protection for A input: 11 A, 1000 V FAST, min. interrupt rating 20,000 A
3. Temperature: operating: 0 °C to 40 °C; storage: -30 °C to 60 °C indefinitely (to -40 °C for 100 hours)
4. Fuse protection for mA μA inputs: 500 mA, 1000 V FAST, min. interrupt rating 20,000 A
FLUKE F17B+ 17B+ Digital Multimeter Meter

FLUKE F17B+ 17B+ Digital Multimeter Meter Specifications:

1. Operating altitude: 0 to 2000 meters
2. Temperature coefficient: 0.1 X (specified accuracy)/ °C (<18 °C or >28 °C)
3. Display: Digital: 4000 count updates 3/sec
4. Electromagnetic compatibility: complies with FCC part 15, class B, IEC 61326, 3 V/m, performance criterion B
5. Relative humidity: non-condensing < 10 °C; 90% from 10 °C to 30 °C; 75% from 30 °C to 40 °C
6. Relative humidity, 40 MΩ Range: 80% from 10 °C to 30 °C; 70% from 30 °C to 40 °C
7.Battery type: 2 X AA, NEDA 15A, IEC LR6
8. Rated transient overvoltage: 4 KV (1.2 x 50 μs) Peak for measurement Categories I, II, and III.
9.Battery life: Alkaline: 500 hours
10. Weight: 15 once (less than 1 LB)
11. Size (H*W*L): 7 " * 3.5" * 2" (with holster)
12. Certifications: CMC,
13. Safety Compliance: IEC 61010-1, 2000 CAT I 1000 V, CAT II 600 V, and CAT III 300 V over voltage standards
14. Over-voltage installation categories per IEC 61010-1, 2000: the meter is designed to protect against transients in these categories
15. CAT I: From high-voltage low-energy sources, e.g., electronic circuits or a copy machine.
16. CAT II: From equipment supplied from the fixed installation, e.g., Televisions, PCs, portable tools and household appliances.
17. CAT III: From equipment in fixed equipment installations, e.g., installation panels, feeders and short branch circuits, and lighting systems in large buildings.

 Accuracy Specifications:
 
Accuracy is specified for one year after calibration, at operating temperatures of 18 °C to 28 °C, relative humidity at 0 % to 75 %. Accuracy
Specifications take the form of: ±([% of Reading] + [Number of Least Significant Digits])

Function Range Resolution Accuracy
Model 15B Model 17B
AC Volts (40 to 500 Hz) v 400.0mV 0.1mV 3.0%+3 3.0%+3
4.000 V 40.00 V
400.0 V 1000 V
0.001 V 0.01 V
0.1 V 1 V
1.0%+3 1.0%+3
DC Millivolts M 400.0 mV 0.1 mV 1.0 % + 10 1.0 % + 10
DC Volts V 4.000 V 40.00 V
400.0 V 1000 V
0.001 V 0.01 V
0.1 V 1 V
0.5 % + 3 0.5 % + 3
Diode Test 1.000 V 0.001 V 10 % 10 %
Temperature 3 °C (K-type thermocouple) 50 °C to 400 °C
0 °C to 50 °C
-55 °C to 0 °C
0.1 °C NA 2 % + 1 °C
± 2 °C 9 %
+ 2 °C
Resistance (Ohms) 400.0 Ω 4.000 kΩ 40.00 kΩ
400.0 kΩ 4.000 MΩ
40.00 MΩ
0.1 Ω 0.001 kΩ
0.01 kΩ 0.1 kΩ
0.001 MΩ  0.01 MΩ
0.5 % + 3
0.5 % + 2
0.5 % + 2
0.5 % + 2
0.5 % + 2
1.5 % + 3
0.5 % + 3
0.5 % + 2
0.5 % + 2
0.5 % + 2
0.5 % + 2
1.5 % + 3
Capacitance 4 c 50.00 nF 500.0 nF
5.000 µF 50.00 µF 100.0 µF
0.01 nF 0.1 nF
0.001 µF 0.01 µF 0.1 µF
2 % + 5
2 % + 5
5 % + 5
5 % + 5
5 % + 5
2 % + 5
2 % + 5
5 % + 5
5 % + 5
5 % + 5
Frequency Hz (10 Hz -100 kHz) 50.00 Hz 500.0 Hz
5.000 kHz 50.00 kHz 100.0 kHz
0.01 Hz 0.1 Hz
0.001 kHz 0.01 kHz 0.1 kHz
NA 0.1 % + 3
Duty Cycle 0.1 % to 99.9 % 0.1% NA 1% typical 5
1. Manual and Auto Range.
2. Diode test open circuit test voltage is 1.1 V to 1.6 V and short circuit current is < 0.6 mA (typical).
3. Temperature specifications do not include thermocouple errors. After inserting the thermocouple plug into the meter, allow several minutes for thermal stabilization.
4. Specifications do not include errors due to test lead capacitance and capacitance floor (may be up to 1.5 nF in the 50 nF range). For the 17B, errors can be reduced by using the relative feature.
5. For values between 10% and 90% duty cycle at 50 Hz.
6. When in the 4A range, display will show 4000 counts, please ignore the last digit.

Function Range Resolution Accuracy
Model 15B Model 17B
AC Current (40 to 200 Hz) 400.0 µA 0.1 µA 1.5%+3 1.5%+3
4000 µA 1 µA
AC Current (40 to 200 Hz) 40.00 mA 0.01 mA 1.5%+3 1.5%+3
400.0 mA 0.1 mA
AC Current (40 to 200 Hz) 4.000 A6 10.00 A 0.01 A 0.01 A 1.5%+3 1.5%+3
DC Current 400.0 µA 0.1 µA 1.5%+3 1.5%+3
4000 µA 1 µA
DC Current 40.00 mA 0.01 mA 1.5%+3 1.5%+3
400.0 mA 0.1 mA
DC Current 4.000 A6 0.01 A 1.5%+3 1.5%+3
10.00 A 0.01A

Function Overload Protector Input Impedance (Nominal) Common Mode Rejection Ratio Normal Mode Rejection
AC Volts V 1000 V >10 MΩ <100 pF >60 dB at dc, 50 or 60 Hz  
DC Volts V 1000 V >10 MΩ <100 pF >100 dB at dc, 50 or 60 Hz >45 dB at 50 or 60 Hz
106 V Hz Max        
 
Standard Accesorries:
 
1. A Pair of Original Test leads
2. Thermocouple
3. True FLUKE F17B+ meter
4. Free black carrying bag
5. Original User Manual
6. Batteries
 
Packing Including:
 
1set x  FLUKE F17B+ 17B+ Digital Multimeter Meter 
 


If you have any questions, please feel free to contact us by following way:

Email: Sales@iDiyTools.com
Whatsapp: 0086-18046220975

Shipment Warm Tips:

We only ship to the address on Paypal. If you require a specific address to ship the order to, please make sure that you enter this in the Paypal confirmation before confirming payment. We will not ship to any other address under any circumstances. If you have asked for a change in address please add your shipping address on your paypal account,please leave a message on paypal when you check out, or send us the screen shot of new shipping address under paypal account to sales@iDiyTool.com or whatsapp:+86 18046220975.
Buy more and Save more
Customers who viewed this item also viewed